Dometic CoolFreeze Cooler & Freezer CFX-WD Wireless Display. Batteries Or 12V. Works with Dometic Cool Freeze coolers. New in box.
The wireless display CFX-WD allows data, such as the current temperature, power supply or alarm, to be shown up to 15 m away from the CFX cooler.
Operating and display elements
Description
P a
°C/°F button SET button
+/– buttons
Explanation
LED lights up green:
LED lights up orange:
LED flashes red:
Switches between °C and °F
• Show set cooling temperature (SET) • Set temperature alarm (ALERT)
• Switchwirelessdisplayon/off(ON/OFF)
• The+/–buttonssetthetemperaturealarm.
• The – button switches the backlight on and off. • The+buttonturnson/offthealarmsound.
Compressor is on
Compressor is off
Device is switched on but not ready for operation
Operating the wireless display
Selecting the temperature unit
✓ Pressthe“°C/°F”buttontoswitchbetween°Cand°F.
Showing the current temperature/power supply
The display indicates the current temperature of the cooler. When the cooler is connected to a 100 – 240 V AC mains supply, the display shows “AC”. When the cooler is operated with 12/24 V DC, the display shows the input voltage and the mode set for the battery monitor
(VH – HIGH, VM – MEDIUM, VL – LOW).
Showing the set temperature
➤ Pressthe“SET”buttononce.
✓ Thedisplayindicatesthesetcoolingtemperature.
Setting the temperature alarm
➤ Pressthe“SET”buttontwice.
➤ Pressthe“+/–”buttonstosetthetemperaturealarm
(“OFF”: no alarm, “01”: alarm at ± 5 °C/°F, “02”: alarm
at ± 3 °C/°F).
Switching the wireless display on/off
➤ Pressthe“SET”buttonandholditdownfortwo seconds.
✓ Thedisplayisswitchedonoroff.
The backlight is automatically switched off during battery operation.
Alarm for temperature, battery and temperature sensor
When the current temperature is outside the set temperature, the “ALERT” message appears, the display flashes and an alarm sounds. Press the “+” button to switch off the alarm.
Technical data
When the battery voltage is insufficient, the “P” LED flashes orange and the mode indicator for the battery monitor flashes.
The fault messages “E1” (interrupted power circuit) and “E2” (short circuit) are shown on the display if there is a fault with the temperature sensor.
Ref. no.:
Response time:
Range:
Input voltage:
Connected voltage versus batteries:
Current consumption:
LCD display:
CFX-WD
9105306632
5s
15m
12/24 Vg
(range: 9 V – 31.5 Vg)
(1,8 m lead/cigarette plug included)
3 Vg (2 standard AAA 1.5 V batteries included)
When connected to 12/24 Vg, batteries are not in use.
HINT: Connection to 12/24 Vg as often as possible will prolong battery life.
50 mA (12/24 Vg) 15 mA (batteries)
1 mA (stand-by)
Blue backlight with 12/24 Vg connected No backlight when battery powered