3 Column Outdoor Cooling Aircon
Industrial Portable Spot Cooler Air Conditioner This machine is suitable for hospitals,
research institutes, disaster scene ambulances, automobile repair centers,
manufacturing engineering cooling, temporary offices such as reception rooms,
equipment centralized cooling, factory production workshops, canteens,
warehouses, on-site offices, outdoor activities such as golf practice Fields,
various celebrations, temporary greenhouses, etc. Dimension 21.65"*24.41"*49.6" (55cm*62cm*126cm) Voltage 220V Amp 10.8A Btu/h 22178 Air
Flow 910m³/h Use
environment 18℃~45℃ Power 2400W Refrigerant R410A Weight 220lbs This machine is equipped with 2 universal
wheels with foot brake, which is more convenient for steering and
moving. This machine is equipped with 2 directional
wheels without foot brake, which is more convenient to move. Variable air vents with free direction Soft air outlet, adjustable in length
and direction, placed more freely, and not picky in usage
environment. This machine is equipped with a controller,
which can start the machine with one click, with adjustable air volume, cold air
temperature, and environmental temperature. This machine is equipped with a high-efficiency
evaporator with a detachable filter screen for easy
cleaning. BIG WATER TANK(14L) This machine is equipped with a water
tank that can receive condensate water, making it easy to see the amount of
water and discharge it in a timely manner. Ad opting technical welding and surface painting, the appearance is
more visible. Centrifugal fan Adopting high-quality aluminum blades with
strong wind power, uniform airflow, and low noise. The condensed water is connected to the water,
and the condensed water flowing out of the machine can be stored here. It is
necessary to observe the water volume in the bucket in a timely manner and pour
it out in a timely manner. High quality compressor Adopting a high-quality
fully enclosed rotary compressor, it has strong functionality and excellent
performance, and can effectively cool in a high temperature environment of 45
℃. Precautions: 1. This product is industrial
cooling and air-conditioning equipment, not a houseware. 2. This product is a local
cooling air-conditioning equipment. The cooling and heat dissipation are on the
same machine, which is different from the traditional household split air
conditioner. This machine
cannot cool the whole space (if the whole space needs to be cooled down, it is
necessary to install pvc hose or aluminum foil single tube at the hot air outlet
to discharge the hot air outside,this model needs to choose a 45cm size
hose) 3. The design and use
environment of this product is 18-45℃. If the temperature is lower than or
higher than this temperature zone, the equipment will not operate normally, not
the product itself is malfunctioning. 4. The noise of this product is
60-70 decibels, which is not suitable for occasions that require noise (such as
bedrooms, meeting rooms, offices, libraries, etc.). Method of operation: ●Power switch Turn on the power, the power switch
indicator light is on, press the button to turn on and off the
machine. ●Air volume selection Press the button to choose
automatic wind ●Cold air temperature setting Press the cold air
temperature setting key, and the cold air temperature indicator will light up at
the same time. At this time, press the upper and lower temperature adjustment
buttons to set the desired outlet air temperature, that is, run in the cold air
set temperature mode. The cold air temperature can be set from 0°C to 30°C. When
the cold air temperature is 1°C higher than the set temperature, the compressor
works and the air outlet outputs cold air; when the cold air temperature is 1°C
lower than the set temperature, the compressor stops working and the air outlet
outputs natural air. ●Environmental temperature setting Press the
button, the machine detects and displays the inlet air temperature, and the
inlet air temperature indicator lights up at the same time. Press the upper and
lower temperature adjustment buttons to set the desired inlet air temperature,
that is, run in the inlet air set temperature mode, and the inlet air
temperature can be set from 18°C to 35°C. When the inlet air temperature is
1°C higher than the set temperature, the compressor works, and the air outlet
outputs cold air; when the inlet air temperature is 1°C lower than the set
temperature, the compressor stops working, and the air outlet outputs natural
air. ●Alarm indicator When the machine is full of water,
overcurrent, overheating, or ultra-high pressure, the alarm indicator will light
up, the machine will stop running, and the LED display will show the
corresponding fault code. Maintenance and
inspection: Please
clean the filter regularly. If dust and dirt accumulate on the filter, it will
affect the air intake, easily cause frost on the heat exchanger, affect the
cooling effect, and cause the machine to malfunction. ●To clean
the filter, please lift the filter up and then take it out directly. Use a
vacuum cleaner to absorb the dust on the filter, then clean it with water or a
neutral detergent, and restore it to use after it is completely dry. Note!!!! When
cleaning the surface of the machine, do not use chemicals such as thinner,
volatile oil, etc., otherwise it will affect the appearance of the
machine. ● Please always check whether the parts and screws are
loose. If there is any looseness, please tighten it in time to remove it. Before
the machine is not used for a long time, please pour out the accumulated water
in the water storage bucket and store it after the machine is
dry. ●Do not
store the machine horizontally or upside down. ●Please
keep the machine out of the reach of children, and avoid storing it in places
subject to high temperature, splashing rain and direct sunlight. ●During
maintenance and inspection, be sure to cut off the power supply. ●Be sure
to cut off the power supply when storing the machine. On Aug 10, 2023 at 04:01:56 PDT, seller added the following information: